Facility Instruments

Mimir

  • the primary near-IR instrument for the Perkins telescope
  • instrument website: http://people.bu.edu/clemens/mimir/
  • two imaging modes, spectroscopy, and broadband linear polarization
  • detector: Raytheon ALLADIN 1024×1024 InSb, 20 micron pixels
  • wavelengths: 0.8 to 5.0 microns
  • fields of view: 10 x 10 arcmin and 3 x 3 arcmin
  • pixel scales: 0.58 arcsec/pixel and 0.18 arcsec/pixel
  • imaging filters: MKO JHKsL’M’, H2S1 (on/off)
  • spectral resolution: R = 120 to 550
  • spectral coverage: 1.16 microns to 5.6 microns
  • polarimetric efficiency: 91.2 ± 2.5%
  • average instrumental polarization: 0.35 ± 0.02%
  • detector: Raytheon ALLADIN III InSb, 1024×1024 20-micron pixels

The Perkins Re-Imaging SysteM (PRISM)

  • the primary optical instrument for the Perkins telescope
  • instrument website: http://www.bu.edu/prism/
  • imaging, slit/multi-object spectroscopy, broadband linear polarization
  • wavelengths: 3500-9500 Angstroms
  • detector: e2v 230-42 back-illuminated CCD, 2048×2024 15-micron pixels
  • field of view: 13.65 x 13.65 arcminutes
  • pixel scale: 0.39 arcsec/pixel
  • imaging filters: 5 slots, options for Johson-Cousins UBVRI, SDSS ugriz, Hα on/off, and BG40
  • spectral resolution: R = 140 to 850
  • spectral coverage: 350 nm to 950 nm